2024 Engtips - Subject: Section VIII-1, UCS-85 (b) and (e) Date Issued: May 31, 1984. File Number: BC82-563. Related Documents: Question (1): A dished head made of P-No. 1 Gr. Nos. 1 and 2 material with a thickness of less than 1¼ in. is hot pressed at a temperature of 1750°F. Are test specimens required under UCS-85 of Section VIII, Division 1, to ...

 
Student posting in Eng-Tips forums for help with theses or coursework is forbidden. This is considered cheating. Offending posts will be removed from the site and offending members will lose their membership privileges. Posting. Commercial and/or recruiting "spam" will not be tolerated in the forums. Our forums are member-policed via the forums' "Red-Flag" …. Engtips

Headed stud vs. deformed bar as an anchor. On the left is a headed stud that we can say is governed by concrete tension breakout. On the right is a deformed rebar with an embedded length equal to ld per 25.4.2.3 of ACI 318-14. Let's say I wanted to design an anchor for a wall.Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: SOLIDWORKS 3D Design. Includes problem solving collaboration tools.A common rule for situations like this is extend the depth of calculation to the point where the added pressure is 10% of existing pressure. the total extent of settlement is informed by soil modulus and the consolidation index (Cc) or consolidation ratio (Cec). If the clay is overconsolidated, then it'd be Cr, or Cer.Will and Mango from Part-Time Genius explore the subject of rudeness — why it's dangerous to our health and why we can't stop thinking about it. Advertisement Someone cuts you off ...Joints spacing: • Rule of thumb is 24 to 36 times the thickness (gives the spacing in mm/inches). • Keep the thickness variation to -5mm (-1/4") / +10mm (3/8"), and the subgrade as flat as possible with no abrupt change greater than 15mm (1/2") in about 1.2m (4'). This keeps the "sudden" restraint potential down.Eng-Tips. 291 likes · 1 talking about this. ENG-TIPS FORUMS: GIVING NEW MEANING TO "VALUE ENGINEERING"Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …The kitchen in question is for a residential hall at a college. 2. bookowski (Structural) 17 Feb 13 21:18. Commentary for ASCE7 provides additional occupanies/situations. It lists "Kitchen, other than domestic = 150psf" with a note to use the actual equip. weight if greater. WWTEng (Structural)Analyze the purlin as a beam with fixed ends and design your connection for that moment with a healthy amount of extra capacity. I am using the current code required snow loads. In my area, the required snow load is 35psf, so I am not overly worried about wind. JStructsteel (Structural) 1 Nov 22 12:45.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Hi all, I'm designing a diesel tank 14m Diameter, 15m high tank with a fixed roof (rafters and roof plate). Max inlet flow rate = 870 m^3/h DN250 Max outlet floEfficiency (measured in stiffness or strength per unit of weight) is not highest with compact sections - it is actually quite the opposite. Class 3 sections, for example, rarely require transverse or longitudinal stiffeners, but the larger web depth acquired with them far offsets any issues relating to elastic section capacity or local buckling.Makes sense to do so. EIT. hawkaz (Structural) 1 Sep 11 19:08. 40 psf is a good number. 4000# car over a 9'X18' space = 25 psf. I would put the full snow load on the roof in addition to the 40 psf load (both can be there at the same time). msquared48 (Structural) 1 Sep 11 19:45. 6000# (Suburban)over 9X18 is 37.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …As a foundry engineer in a Aluminnum foundry we fight this with customers all the time. #1- Aluminum has roughly 1/2 the Brinell of iron ( hardness) thiss means if you used 6 - 3/8X16 x 1 bolts on a iron part you better look at. using 10 1/2 x 13 x 1.5 in aluminum. We also push Heli coils.U.S. stocks traded higher this morning, with the Dow Jones gaining more than 100 points on Friday. The Dow traded up 0.41% to 33,473.16 while the... U.S. stocks traded higher this...Men's Health offers eighteen tricks that make a body feel better, like how to clear a stuffed nose or make an injection hurt less. Men's Health offers eighteen tricks that make a b...Boiler and Pressure Vessel engineering. (38965 members) forum794 - Professional forum and technical support for engineers for Boiler and Pressure Vessel engineering. Includes problem solving collaboration tools. Forum. Search.Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: ABAQUS FEA Solver. Includes problem solving collaboration tools.My preferred method is to use 3 celas elements for each bolt (2 shears and a tension), and use Huth to obtain the stiffnesses for the FE. The saving grace is that even when you use one of the methods above, in the great scheme of things it makes little difference. RE: Extracting bolt loads from cbush elements. …Strength (whether for LRFD or ASD) for wind load is checked at a 700 year MRI for RC2 structures while service load is generally taken to be a 10 year MRI. That can be about 58% less load than the strength check. Service loads are somewhat discretionary...IBC has basic deflection calculation requirements, but they are not the end …Its total height is 140 mm, where height of steel deck is 60 mm and height of concrete above slabs is 80 mm, so I've put that both membrane and bending thicknesses are 140mm = 0,14m. As a material I've chosen concrete C30/37 defined in Materials (I'll attach my model in SAP2000 at the end of the post). This concrete's Weight per Unit Volume is ...Analyze the purlin as a beam with fixed ends and design your connection for that moment with a healthy amount of extra capacity. I am using the current code required snow loads. In my area, the required snow load is 35psf, so I am not overly worried about wind. JStructsteel (Structural) 1 Nov 22 12:45. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... When you think about shared micromobility, Veo isn’t exactly the first company that comes to mind. It’s not as widespread as competitors like Voi, Tier and Lime, and it hasn’t rais...Eng-Tips. @engtips. The Eng-Tips resource library offers the latest engineering white papers, webcasts, and product information. eng-tips.nethawk.net …smokiibear (Civil/Environmental) (OP) 10 Jan 20 17:08. I'm refering to the specific wording in 7-16, chp 28. Also, I have two structures that will combine to make 1. When the roof is off, I have walls with no roof, and I have a roof with no walls. The roof will slide to another structure without walls, just columns.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …A restrained retaining wall with fixity between the footing and the stem is indeterminate. As the at-rest pressure goes to work on the stem, it's obvious that the horizontal reaction at the top of the wall will increase. If the stem and stem-footing joint are very stiff, they will significantly limit stem deflection and rotation of the stem ...Ignition, Combustion and Detonation engineering. Laser engineering. Mechanical Seal engineering. Mechanical Acoustics/Vibration engineering. Optical systems engineering. Pipelines, Piping and Fluid Mechanics engineering. Pump engineering. Storage tank engineering. Valve engineering.smokiibear (Civil/Environmental) (OP) 10 Jan 20 17:08. I'm refering to the specific wording in 7-16, chp 28. Also, I have two structures that will combine to make 1. When the roof is off, I have walls with no roof, and I have a roof with no walls. The roof will slide to another structure without walls, just columns.SIG:Please see FAQ731-376: Eng-Tips.com Forum Policies for tips on how to make the best use of Eng-Tips. RE: "Break sharp edges" note. berkshire (Aeronautics) 26 Feb 09 19:32. The most common tool for breaking sharp edges in the aircraft industry is a small tool called a Burr Wik, it has a receptacle into which several types of scraper like …Joints spacing: • Rule of thumb is 24 to 36 times the thickness (gives the spacing in mm/inches). • Keep the thickness variation to -5mm (-1/4") / +10mm (3/8"), and the subgrade as flat as possible with no abrupt change greater than 15mm (1/2") in about 1.2m (4'). This keeps the "sudden" restraint potential down.22 hours ago · The Eng-Tips staff will check this out and take appropriate action. Close. Reply To This Thread Posting in the Eng-Tips forums is a member-only feature. Pressure/temperature ratings for Class 800 shall be determined by the equation: P8 = 1/3 P6 + 2/3 P9. where. P8 is the pressure at the specified temperature, expressed in bar3, for Class 800 rounded to the nearest. (10 kpa); P6 is the listed pressure, at the specified temperature, for Class 600, expressed in bar;Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng …From raising minimum wages to "staple green cards." The allocation of H-1B visas is very inefficient, with the lottery system being used in the years with the greatest visa demand—... Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: SOLIDWORKS 3D Design. Includes problem solving collaboration tools. The reason is carbon content below 0.03% would be considered 304L per the SA 240 material specification, and limited to 1000 deg F. When you have dual grade certification 304L/304, the 0.04% or higher carbon comes into play for creep strength and one must review the MTR for specific use. SnTMan (Mechanical) 14 … Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for ASME (mechanical) Code Issues. Includes problem solving collaboration tools. (RTTNews) - Himax Technologies, Inc. (HIMX) reported that its second quarter profit to stockholders declined to $70.64 million from $108.89 millio... (RTTNews) - Himax Technologies...ISZ, Thanks for the reply. I contacted the manufacturer and they recommended pointing the arrow toward the sky. The most apparent difference with the orientaion is the voltage output when the cell is loaded. If the arrow is down, the voltage is negative, if pointed up, the voltage is positive.Mar 2, 2021 · Collaborate with other engineers! Their input will help you overcome mental hurdles and refine your designs. Plus, brainstorming with others is an excellent way to uncover innovative solutions to long-standing engineering issues. A great online resource is eng-tips.com. #13 Over-communicate Stay connected with all the key players in a project. Chemical process engineering. (26899 members) forum798 - Professional forum and technical support for engineers for Chemical process engineering. Includes problem solving collaboration tools. Forum. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Steel Stair Seismic Design. I have posted a couple of threads regarding this subject in the past, but I would like to post a more thourough question regarding providing seismic design on steel stairs. I have a particular project which is in the Missouri area and is governed by the 2006 IBC and ASCE 7-05. I have …Engine & fuel engineering. (30295 members) forum71 - Professional forum and technical support for engineers for Engine & fuel engineering. Includes problem solving collaboration tools. Search.The new search is useless, but hopefully the features of the legacy search will be reinstated soon. CWB1 (Mechanical) 28 Jan 24 16:22. I usually have better luck applying search codes like "site:eng-tips.com" in a commercial search engine like google, duckduckgo, etc rather than version of those same engines that are on the websites …Dystonia is a movement disorder. It causes involuntary, often painful, contractions of your muscles. Learn about causes, symptoms, and what can help. Dystonia is a movement disorde...GENEVA (11 March 2024) — Syria is experiencing a wave of violence not seen since 2020, the UN Syria Commission of Inquiry warned in a report released today. …Although not directly applicable for stacks TIA/EIA-222 'Structural Standards For Steel Antenna Towers And Supporting Structures' states "Initial tension in the guys, for design purposes, is normally 10 percent of the published breaking strength of the strand with upper and lower limits of 15 and 8 percent …Start with the loaded front wheel loads. The 8000 pounds is presumably the lift capacity and not the total loaded weight. Looking at the contact patch on the loaded front tires will give you a sense of the local punching and beam shear demand-to-capacity ratios.Eng-Tips. @engtips. The Eng-Tips resource library offers the latest engineering white papers, webcasts, and product information. eng-tips.nethawk.net …You mean we can directly draw a cantilever beam with one end attached to a beam or column while the other end attached to nothing? The beam end is default to be fixed or pinned? slickdeals (Structural) 4 Nov 08 08:11. In ETABS, things are fixed by default unless specified explicitly to be pinned.(RTTNews) - Himax Technologies, Inc. (HIMX) reported that its second quarter profit to stockholders declined to $70.64 million from $108.89 millio... (RTTNews) - Himax Technologies...I have modelled a pond with an outlet control structure consisting of a low flow orifice (Flowing to Device 1) and sharp crested weir (Also flowing to Device 1) discharging to a culvert (Modelled as the Primary). The report states that the weir and the orifice are controlling the flows and the culvert passes XXX of XXX …We are designing two building and we have two close columns in between so we are going to design these two columns on one pile cap with one pile. (2columns are 200 kips and 100 kips, clay soil, end bearing 4000 psi, skin friction ignored, Pile Diameter shaft is 3.3ft,bell is 10ft) we can not make it two piles …JAE (Structural) 9 Feb 11 21:01. Sounds like you got it. wannabeSE (Civil/Environmental) 9 Feb 11 21:13. If you are anchoring the equipment to masonry or concrete, look at ASCE 7-05 section 13.4.2. You may need to multiply the seismic force by 1.3. Also, if the anchors are not prequalified for seismic, you may need to … Activities. Civil/Environmental engineering general discussion. Climate Change Engineering Solutions. Earthwork/grading engineering. Soil/Groundwater environmental engineering. Storm/Flood engineering. Surveying & Geomatics. Traffic Engineering. Waste disposal & treatment. Fluid Power engineering. (8474 members) forum1083 - This group is to allow those who use hydraulics and/or pneumatics to exchange ideas and information that will assist in their proper use and that the discussions will illustrate the need for and promote interest in gaining appropriate certification. Forum. Search. Ignition, Combustion and Detonation engineering. Laser engineering. Mechanical Seal engineering. Mechanical Acoustics/Vibration engineering. Optical systems engineering. Pipelines, Piping and Fluid Mechanics engineering. Pump engineering. Storage tank engineering. Valve engineering. Eng-Tips. @engtips. The Eng-Tips resource library offers the latest engineering white papers, webcasts, and product information. eng-tips.nethawk.net …To ask an engineering question please visit our forum site at Eng-Tips. Browse our archive of questions and answers below or to access our old forum database of over 10000 questions and answers please visit the old Ask@ forum. Forums; Search; Unanswered; Active Topics; Engineering Questions and Answers: Forums: Topics: Replies: Last Post: …At the moment we have 870525 registered users, who have published 99622 materials and shared 554052 comments. Englishtips.org was launched in 2005. In the last 24 hours …You mean we can directly draw a cantilever beam with one end attached to a beam or column while the other end attached to nothing? The beam end is default to be fixed or pinned? slickdeals (Structural) 4 Nov 08 08:11. In ETABS, things are fixed by default unless specified explicitly to be pinned.JStephen (Mechanical) 13 Feb 17 15:46. If you don't find anything specific to this situation-. Treat the flange as a triangular wedge spreading out at 45 degrees each side from the bolt hole and checking bending at the web. For a one-off design, it may be cheaper to weld a stiffener in than to show it isn't needed.Eng-Tips Forums is an English-language knowledge market website that allows users to post engineering-related questions to be answered and answer questions asked by other …UcfSE (Structural) 29 Nov 06 21:52. A good limit for live load deflection is 3/4-inch. You don't want to squash your interior partitions either, besides just the windows and such in the exterior walls. Some manufacturers have products designed to go allow more than 3/4 inches of deflection but it isn't the norm.Dystonia is a movement disorder. It causes involuntary, often painful, contractions of your muscles. Learn about causes, symptoms, and what can help. Dystonia is a movement disorde... Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Hi all, I'm designing a diesel tank 14m Diameter, 15m high tank with a fixed roof (rafters and roof plate). Max inlet flow rate = 870 m^3/h DN250 Max outlet floChina and Europe remain the most important electric vehicle markets. Electric vehicles (EVs for short) are no longer just cool toys reserved for wealthy futurists. They are becomin...Joel - I tried to configure (imagine) a non-prestressed concrete tank that had H^2 / Dt > 50. Hard to do. For both the considerations of the combined shear + flexural demand at the base, and shrinkage, tall non-prestressed concrete tanks are uncommon, and I certainly would try to persuade you toward either steel or prestressed (DYK / DN) Type …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register … Safety Relief Valve engineering (PSV) (8427 members) forum1203 - Professional forum and technical support for engineers for Safety Relief Valve engineering (PSV). Includes problem solving collaboration tools. Forum. Defying stereotypes. At four feet 11 inches, and 73 kilograms, Dolly Singh stands out from the crowd of star yogis on Instagram who have come to be known for their slim waists, mus...Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Engtips

JAE (Structural) 9 Feb 11 21:01. Sounds like you got it. wannabeSE (Civil/Environmental) 9 Feb 11 21:13. If you are anchoring the equipment to masonry or concrete, look at ASCE 7-05 section 13.4.2. You may need to multiply the seismic force by 1.3. Also, if the anchors are not prequalified for seismic, you may need to …. Engtips

engtips

RE: Retaining wall backfill. pond68 (Structural) (OP) 12 May 10 15:37. Typically that's what I always recommend. RE: Retaining wall backfill. cvg (Civil/Environmental) 12 May 10 15:52. to get 75% with normal concrete will require somewhere between 7 - 14 days. Most contractors will not want to wait that long.Earthwork/grading engineering. (18515 members) forum158 - Professional forum and technical support for engineers for Earthwork/grading engineering. Includes problem solving collaboration tools. Forum.HVAC/R engineering. (27384 members) forum403 - Professional forum and technical support for engineers for HVAC/R engineering. Includes problem solving collaboration tools. Search.UcfSE (Structural) 29 Nov 06 21:52. A good limit for live load deflection is 3/4-inch. You don't want to squash your interior partitions either, besides just the windows and such in the exterior walls. Some manufacturers have products designed to go allow more than 3/4 inches of deflection but it isn't the norm.We are designing two building and we have two close columns in between so we are going to design these two columns on one pile cap with one pile. (2columns are 200 kips and 100 kips, clay soil, end bearing 4000 psi, skin friction ignored, Pile Diameter shaft is 3.3ft,bell is 10ft) we can not make it two piles …All the handrails have to meet the requirements. Loading one side vs the other side is really irrelevant to the handrails and its connections. If there is some loading you are concerned about the in the elements supporting the handrails you might want to consider the loading on each of them simultaneously or perhaps just one side.Heat Transfer & Thermodynamics engineering. (36035 members) forum391 - Professional forum and technical support for engineers for Heat Transfer & Thermodynamics engineering. Includes problem solving collaboration tools. Forum.The caustic scrubber is used to absorb the sour gases like H2S and CO2. To design this, you need to consider the system as an absorption column. For that you need to calculate how many equilibrium stages you have. Do not forget you have , at least, one chemical reaction (H2S + 2NaOH --> Na2S + 2H2O) if your stream doesn't have CO2.Student Engineer General Discussion. (4380 members) forum1630 - Professional forum and technical support for engineers for Student Engineer General Discussion. Includes problem solving collaboration tools. Forum.Just one little thing to type or bookmark, and you'll have a fresh document in front of you. “I’m always doing some terrible workaround to try to get to Docs quickly,” our Senior T...Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for Programmable logic controllers (PLC). Includes problem solving collaboration tools.GENEVA (11 March 2024) — Syria is experiencing a wave of violence not seen since 2020, the UN Syria Commission of Inquiry warned in a report released today. … Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... smokiibear (Civil/Environmental) (OP) 10 Jan 20 17:08. I'm refering to the specific wording in 7-16, chp 28. Also, I have two structures that will combine to make 1. When the roof is off, I have walls with no roof, and I have a roof with no walls. The roof will slide to another structure without walls, just columns.The Bahamas are a staple on warm-weather cruises. Read on for all you need to know when planning a sailing to the cruise industry's most popular destination. If you've cruised or a...Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for Computers and Structures: SAFE. Includes problem solving collaboration tools.The first one is applying point load on the flange and the Beff that can be used for capacity calculation. Mu = P x a. S = beff x t^2 / 6. Mc = phi x fy x S. Second image is the scenario with stiffener added. How do we calculate the capacity for such cases? Thanks.Update: My final solution was to drill and epoxy #3 bars at 24" OC (every 3 CMU courses) with 18" of embedment into the existing walls. However, there was an ice storm in late December that revealed more structural problems with the building only to be exacerbated by the winter storm from February.My preferred method is to use 3 celas elements for each bolt (2 shears and a tension), and use Huth to obtain the stiffnesses for the FE. The saving grace is that even when you use one of the methods above, in the great scheme of things it makes little difference. RE: Extracting bolt loads from cbush elements. …John Werner. 2023, the writer argues, was the year in which we learned in a theoretical way about how large language models work. 2024, by contrast, is going to be …Hot dip galvanized anchor bolts should be used if corrosion is a concern. Do not have regular black anchor rods galvanized, since the clearances would not be correct. As stated above, you can also coat the exposed portions with grease, paint, gooey-anti-corrosion-stuff, or whatever after fastening, but not before. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Just one little thing to type or bookmark, and you'll have a fresh document in front of you. “I’m always doing some terrible workaround to try to get to Docs quickly,” our Senior T...LB.HESSEN-THÜRINGEN GZZINSDIFF.ANL.07C/19-07 V19(34) (DE000HLB33W0) - All master data, key figures and real-time diagram. The Landesbank Hessen-Thüringen Girozentrale-Bond has a ma...Dystonia is a movement disorder. It causes involuntary, often painful, contractions of your muscles. Learn about causes, symptoms, and what can help. Dystonia is a movement disorde...One of the restrictions is to limit the the bead width to 4x core wire diameter. SJones (Petroleum) 3 Jul 08 13:40. Indeed it is: in item (f), 4, a). My apologies for missing this very specific case since it is adopted as the norm for all our vessel and piping SMAW welding. Steve Jones. Materials & Corrosion Engineer.Headed stud vs. deformed bar as an anchor. On the left is a headed stud that we can say is governed by concrete tension breakout. On the right is a deformed rebar with an embedded length equal to ld per 25.4.2.3 of ACI 318-14. Let's say I wanted to design an anchor for a wall.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …4 steps is then only 1750mm clearance and step 5 about 1500mm - too low. Basically you made the hole too small to get the angle of stairs that are suitable for a domestic property ( max angle seems to be about 38 degrees). To get the clearance of 2m under the lip you need about 52-55 degrees.Engineering Reference. Free Engineering Books Pdf Is The Best Wanted Website For All Engineers. Download Free Engineering Books Online Which Related To All Engineering …PE Civil Structural Exam Study Advice9. Hello All! I am preparing to take the PE Civil Structural exam for the first time in October 2021. Please reply with what each of you used to study and pass the exam. I have found a lot of engineers who recommend the CERM book and NCEES Civil Structural Practice Exam book.GEE8B (Structural) 29 Apr 23 08:33. Dead load is always downward (direction of gravity). Wind load can be upward or downward (suction/pressure). Wind forces away from the surface are (-). Wind forces towards the surface are (+). So the “W” in 0.6D+W can be negative or positive. Pressure and suction values are typically per ASCE7, and it is ... Pats' Pub *. Translation Assistance for Engineers. * Invite-Only Groups that are publicly listed allow you to browse the Group, but you must apply for Group membership before participating in it. Eng-Tips engineering forums is an intelligent work forum community for engineering professionals of all disciplines. Brick grows with time, and that can lead to cracking at the thinnest sections, and the two sections in your photos are thin. This cracking in veneer is not indication of settlement or other structural problems, so if it bothers you, get a mason to repoint it. Make sure he knows what he is doing, as amateur repairs can stand out worse than the ...Specifically, bollards for protection are angled toward the direction of the expected threat; this provides an added measure of strength, since there's no reason to make the bollards be symmetrical in protection direction/angle. Angling the bollard could reduce the required thickness of the bollard, since the collision energy is directed ...Heat Transfer & Thermodynamics engineering. (36035 members) forum391 - Professional forum and technical support for engineers for Heat Transfer & Thermodynamics engineering. Includes problem solving collaboration tools. Forum.Jan 3, 2021 · PE Civil Structural Exam Study Advice9. Hello All! I am preparing to take the PE Civil Structural exam for the first time in October 2021. Please reply with what each of you used to study and pass the exam. I have found a lot of engineers who recommend the CERM book and NCEES Civil Structural Practice Exam book. One of the restrictions is to limit the the bead width to 4x core wire diameter. SJones (Petroleum) 3 Jul 08 13:40. Indeed it is: in item (f), 4, a). My apologies for missing this very specific case since it is adopted as the norm for all our vessel and piping SMAW welding. Steve Jones. Materials & Corrosion Engineer.PE Structural CBT April 2024. I am beginning to study for the the new PE Structural (SE) exam that is a computer based test (CBT) beginning in April 2024. All prep courses I have seen online are for the existing SE exam. I am wondering if anyone else is studying for the new format SE exam and how you are going about studying.Indian women are more educated than they have ever been. Yet, the latest figures show that fewer of them are working. Indian women are more educated than they have ever been. Yet, ... Safety Relief Valve engineering (PSV) (8427 members) forum1203 - Professional forum and technical support for engineers for Safety Relief Valve engineering (PSV). Includes problem solving collaboration tools. Forum. Start with the loaded front wheel loads. The 8000 pounds is presumably the lift capacity and not the total loaded weight. Looking at the contact patch on the loaded front tires will give you a sense of the local punching and beam shear demand-to-capacity ratios.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Eng-Tips aims to support students’ professional and academic development. Eng-Tips is a forum for engineering professionals and students of all disciplines. (Stock photo.)Petroleum engineering general discussion. (13755 members) forum481 - Professional forum and technical support for engineers for Petroleum engineering general discussion. Includes problem solving collaboration tools.Civil/Environmental engineering general discussion. (46845 members) forum194 - Professional forum and technical support for engineers for Civil/Environmental engineering general discussion. Includes problem solving collaboration tools. Forum.Mar 22, 2023 · From reading XR250s posts I think this is how he approaches it as well. 3. YoungGunner (Structural) 23 Mar 23 15:22. Having worked in residential for 7 years now, I have a few thoughts on the matter: First off, the IRC already shows questionable engineering compared to our "big boy" design standards/codes. The first one is applying point load on the flange and the Beff that can be used for capacity calculation. Mu = P x a. S = beff x t^2 / 6. Mc = phi x fy x S. Second image is the scenario with stiffener added. How do we calculate the capacity for such cases? Thanks.SIG:Please see FAQ731-376: Eng-Tips.com Forum Policies for tips on how to make the best use of Eng-Tips. RE: "Break sharp edges" note. berkshire (Aeronautics) 26 Feb 09 19:32. The most common tool for breaking sharp edges in the aircraft industry is a small tool called a Burr Wik, it has a receptacle into which several types of scraper like …hybrid steel/CLT structure. I'm looking to get a better understanding of using CLT deck with gyp concrete topping, supported by steel beams and columns for a five story institutional building. Specifically, what to pay attention to when using the CLT as a floor diaphragm sending lateral forces to concrete shear walls or braced frames for the LFRS.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register …It's defined in chapter 14 for ASCE 7-05 as a wall segment with a horizontal length-to-thickness ratio of at least 2.5, but not exceeding 6, whose clear height is at least two times its horizontal length. Believe the definition in ASCE 7-10 is the same. Essentially a wall pier is a portion of an overall wall that would have a …The underlying soils are saturated clayey sand soils (SC). The fill material is a slightly silty sand (-200=12 to 15%) with a modified proctor of 119 pcf and 11% moisture. We have two feet of fill in above the wet clayey soils (SC). The fill material was tested to be at 96 to 98% compaction of the modified proctor …4 steps is then only 1750mm clearance and step 5 about 1500mm - too low. Basically you made the hole too small to get the angle of stairs that are suitable for a domestic property ( max angle seems to be about 38 degrees). To get the clearance of 2m under the lip you need about 52-55 degrees.smokiibear (Civil/Environmental) (OP) 10 Jan 20 17:08. I'm refering to the specific wording in 7-16, chp 28. Also, I have two structures that will combine to make 1. When the roof is off, I have walls with no roof, and I have a roof with no walls. The roof will slide to another structure without walls, just columns.Structural engineering general discussion. (83014 members) forum507 - Professional forum and technical support for engineers for Structural engineering general discussion. Includes problem solving collaboration tools.I want to summarize as follows: Rule 1) The direction of the coordinate axis should align with the direction from "Grid A to Grid B" of the bush element. Rule 2) The "positive" direction of your coordinate system …Hi all, I'm designing a diesel tank 14m Diameter, 15m high tank with a fixed roof (rafters and roof plate). Max inlet flow rate = 870 m^3/h DN250 Max outlet flo Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Earthwork/grading engineering. (18515 members) forum158 - Professional forum and technical support for engineers for Earthwork/grading engineering. Includes problem solving collaboration tools. Forum.All the handrails have to meet the requirements. Loading one side vs the other side is really irrelevant to the handrails and its connections. If there is some loading you are concerned about the in the elements supporting the handrails you might want to consider the loading on each of them simultaneously or perhaps just one side.Dystonia is a movement disorder. It causes involuntary, often painful, contractions of your muscles. Learn about causes, symptoms, and what can help. Dystonia is a movement disorde...It's defined in chapter 14 for ASCE 7-05 as a wall segment with a horizontal length-to-thickness ratio of at least 2.5, but not exceeding 6, whose clear height is at least two times its horizontal length. Believe the definition in ASCE 7-10 is the same. Essentially a wall pier is a portion of an overall wall that would have a … Safety Relief Valve engineering (PSV) (8427 members) forum1203 - Professional forum and technical support for engineers for Safety Relief Valve engineering (PSV). Includes problem solving collaboration tools. Forum. Storage tank engineering. (6881 members) forum1452 - Professional forum and technical support for engineers for Storage tank engineering. Includes problem solving collaboration tools. Search. . Carson craigslist